72.5 kV Wall Bushing | NJREC
72.5 kV Wall Bushing | NJREC
72.5 kV Wall Bushing | NJREC

72.5 kV Wall Bushing | NJREC

Item No.: 00888
The 72.5 kV wall bushing carries a conductor through a wall while insulating it from the surrounding structure. Indoor and outdoor configurations can be specified, with mounting and connection dimensions checked for new installations or replacement projec
Description
Description

72.5 kV Wall Bushing

NJREC 72.5 kV wall bushings carry a conductor through a grounded wall or partition while insulating it from the structure. This air-to-air design is specified with an equipment highest voltage (Um) of 72.5 kV under IEC 60137:2017 and a maximum rated current of 4000 A. For new projects or replacements, confirm the mounting and connection dimensions against the installation drawing.

Wall Bushing

Wall Bushing Cross-Section

Wall bushing cross-section

IEC Technical Specifications

Parameter Unit IEC 60137:2017
72.5 kV
Highest voltage for equipment Um kV 72.5
Rated frequency Hz 50/60
Dry power frequency withstand voltage, 1 minute kV 140
Lightning impulse withstand voltage (BIL) kV 325
Switching impulse withstand voltage (SIL) kV –
Maximum rated current A 4000
Temperature range °C Down to −60 °C and up to +55 °C available on request

Contact Us

Factory and Product Photos

Wall Bushing
Wall bushing
Wall bushing factory

Applications

Indoor-to-Outdoor Wall Connections

A 72.5 kV indoor-to-outdoor wall bushing can be specified where a conductor passes from an enclosed electrical room to an outdoor connection. Identify the exposed side and installation environment so the housing and insulation arrangement can be confirmed for the selected model.

Wall Feedthrough Insulation Between Indoor Areas

For a connection between indoor areas, a wall feedthrough insulator separates the live conductor from the surrounding wall or grounded barrier. Check the wall opening, mounting dimensions and terminal positions, especially when replacing an existing unit.

Why Choose NJREC?

NJREC offers a 72.5 kV IEC wall bushing option with a maximum rated current of 4000 A. The conductor, terminals, mounting flange, wall thickness and insulation arrangement can be checked against the project requirements and installation drawing.

For a replacement wall bushing, NJREC can review the original unit’s mounting flange, wall thickness, conductor connections and dimensions on both sides to check fit and electrical compatibility.

FAQ

What are the IEC insulation ratings at 72.5 kV?

The 1-minute dry power frequency withstand voltage is 140 kV, and the lightning impulse withstand voltage (BIL) is 325 kV. 

What current rating is shown?

The maximum rated current shown for the 72.5 kV IEC option is 4000 A. Confirm the required current and connection details for the selected model.

Will it fit an existing wall opening?

Fit must be checked against the mounting and terminal dimensions. Send the existing drawing, wall thickness and opening size for review.

Can the bushing connect an indoor and an outdoor area?

Yes. The 72.5 kV wall bushing can be configured for an indoor-to-outdoor connection. Please provide the wall dimensions and identify which side is exposed outdoors.

Send your message to us
ver_code
pop_close
pop_main
Stay In The Know
Enter your email to hear from us about Product list, Latest Products and Customer application examples!