NJREC supplies DIN porcelain transformer bushings for transformer terminal connections, covering rated voltages from 1 to 52 kV and rated currents from 250 to 8000 A across DIN 42530, DIN 42539, DIN 42531, DIN 42532, DIN 42533, DIN 42534 and DIN 42541. The range includes low-voltage terminal bushings, indoor and outdoor designs, and high-current transformer bushings. Each DIN series has its own ratings and dimensions, as shown below.
NJREC offers 1 kV DIN 42530 porcelain transformer bushings with rated currents from 250 to 3150 A.
| Type | a max. (mm) | b max. (mm) | c (mm) | d (mm) | e (mm) | f (mm) | d1 | d2 (mm) | d3 (mm) | d4 (mm) | d5 (mm) | d6 | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DT 1/250 | 138 | 68 | 25 | . | Ø45 | . | M12 | 28 | 28 | 60 | 50 | . | 1 |
| DT 1/630 | 178 | 82 | 37 | . | Ø63 | . | M20 | 40 | 45 | 85 | 70 | . | 2,4 |
| DT 1/1000 | 263 | 60 | . | 186 | Ø70 | Ø50 | M30×2 | 56 | 56 | 110 | 90 | M10 | 5,4 |
| DT 1/2000 | 340 | 65 | . | 223 | 100 | 60 | M42×3 | 70 | 70 | 125 | 104 | M16 | 12,1 |
| DT 1/3150 | 372 | 70 | . | 230 | 110 | 60 | M48×3 | 80 | 90 | 150 | 125 | M16 | 16,8 |
NJREC offers 3 kV DIN 42539 porcelain transformer bushings with rated currents from 250 to 4500 A.
| Type | a max. (mm) | b max. (mm) | c (mm) | d1 | d2 (mm) | d3 (mm) | d4 (mm) | d5 (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| DT 3/250 | 180 | 94 | 25 | M12 | 28 | 39 | 70 | 75 | 1 |
| DT 3/630 | 210 | 110 | 37 | M20 | 46 | 45 | 85 | 90 | 2,4 |
| Type | a max. (mm) | b max. (mm) | e (mm) | f (mm) | d1 | d2 (mm) | d3 (mm) | d4 (mm) | d5 (mm) | d6 | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DT 3/1000 | 294 | 80 | Ø50 | Ø70 | M30×2 | 56 | 56 | 110 | 110 | M10 | 5,8 |
| DT 3/2000 | 372 | 86 | 60 | 100 | M42×3 | 70 | 70 | 125 | 125 | M16 | 13 |
| DT 3/3150 | 404 | 92 | 60 | 110 | M48×3 | 80 | 90 | 150 | 145 | M16 | 17,5 |
The DIN 42539 3 kV, 4500 A product data are shown in the image above.
NJREC offers 10–30 kV porcelain transformer bushings to DIN 42531 and DIN 42532, with rated currents from 250 to 630 A. The illustrated series includes indoor and outdoor variants.
| Type | Outdoor | Indoor | a (mm) | b (mm) | c (mm) | e (mm) | l1 (mm) | d1 | d2 (mm) | d3 (mm) | d4 | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DT 10 NI 250 | – | 10 N | 260 | 76 | ca. 60 | 85 | 321 | M12 | 78 | 8 | M8 | 3,6 |
| DT 10 NF 250 | 10 N | – | 310 | 76 | ca. 60 | 85 | 371 | M12 | 78 | 8 | M8 | 4,5 |
| DT 20 NI 250 | – | 20 N | 310 | 76 | ca. 60 | 155 | 371 | M12 | 78 | 8 | M8 | 4,6 |
| DT 20 NF 250 | 20 N | – | 385 | 76 | ca. 60 | 155 | 461 | M12 | 78 | 8 | M8 | 6,1 |
| DT 30 NI 250 | – | 30 N | 385 | 76 | ca. 60 | 220 | 461 | M12 | 78 | 8 | M8 | 6,2 |
| DT 30 NF 250 | 30 N | – | 485 | 76 | ca. 60 | 220 | 561 | M12 | 78 | 8 | M8 | 7,5 |
| DT 10 NI 630 | – | 10 N | 292 | 108 | ca. 75 | 85 | 353 | M20 | 90 | 12 | M12 | 5,7 |
| DT 10 NF 630 | 10 N | – | 342 | 108 | ca. 75 | 85 | 403 | M20 | 90 | 12 | M12 | 7,2 |
| DT 20 NI 630 | – | 20 N | 342 | 108 | ca. 75 | 155 | 403 | M20 | 90 | 12 | M12 | 7,3 |
| DT 20 NF 630 | 20 N | – | 417 | 108 | ca. 75 | 155 | 493 | M20 | 90 | 12 | M12 | 9,2 |
| DT 30 NI 630 | – | 30 N | 417 | 108 | ca. 75 | 220 | 493 | M20 | 90 | 12 | M12 | 9,3 |
| DT 30 NF 630 | 30 N | – | 522 | 108 | ca. 75 | 220 | 618 | M20 | 90 | 12 | M12 | 12,2 |
NJREC offers 10–52 kV porcelain transformer bushings to DIN 42533 and DIN 42534, with rated currents from 1000 to 3150 A. The illustrated series includes indoor and outdoor variants.
| Type | a (mm) | b (mm) | d1 | d3 (mm) | d4 (mm) | d5 (mm) | e (mm) | f (mm) | l1 (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| DT 10 NF 1000 | 455 | 158 | M30×2 | 110 | 100 | 163 | 239 | 148 | 541 | 15,2 |
| DT 20 NF 1000 | 530 | 168 | M30×2 | 110 | 100 | 163 | 314 | 148 | 626 | 18,2 |
| DT 30 NF 1000 | 635 | 198 | M30×2 | 110 | 100 | 163 | 419 | 148 | 756 | 21,9 |
| DT 10 NF 2000 | 530 | 158 | M42×3 | 135 | 120 | 183 | 239 | 178 | 616 | 24,9 |
| DT 20 NF 2000 | 605 | 168 | M42×3 | 135 | 120 | 183 | 314 | 178 | 701 | 29 |
| DT 30 NF 2000 | 710 | 198 | M42×3 | 135 | 120 | 183 | 419 | 178 | 831 | 34,7 |
| DT 10 NF 3150 | 560 | 158 | M48×3 | 135 | 120 | 183 | 239 | 183 | 646 | 28,5 |
| DT 20 NF 3150 | 635 | 168 | M48×3 | 135 | 120 | 183 | 314 | 183 | 731 | 32,6 |
| DT 30 NF 3150 | 740 | 198 | M48×3 | 135 | 120 | 183 | 419 | 183 | 861 | 38,8 |
| DT 52 NF 1000 | 725 | 253 | M30×2 | 135 | 120 | 183 | 509 | 148 | 901 | 35,2 |
| DT 52 NF 2000 | 800 | 253 | M42×3 | 135 | 120 | 183 | 509 | 178 | 976 | 44,9 |
| DT 52 NF 3150 | 830 | 253 | M48×3 | 135 | 120 | 183 | 509 | 183 | 1006 | 49,2 |
NJREC offers 24–36 kV DIN 42541 high-current porcelain transformer bushings rated from 5000 to 8000 A.
| Type | Minimum arcing distance (mm) | Minimum creepage distance (mm) | l1 min. (mm) | l2 min. (mm) | l3 min. (mm) | l4 min. (mm) | l5 min. (mm) | l3 min. (mm) | l4 min. (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 24 NF 5000 | 260 | 470 | 540 | 150 | 155 | 295 | 320 | 100 | 100 | 74,3 |
| 24 NF 8000 | 260 | 470 | 570 | 150 | 155 | 295 | 320 | 100 | 130 | 80,2 |
| 36 NF 5000 | 455 | 555 | 635 | 175 | 220 | 320 | 415 | 125 | 100 | 83,3 |
| 36 NF 8000 | 455 | 555 | 665 | 175 | 220 | 320 | 415 | 125 | 130 | 90,1 |



DIN porcelain transformer bushings provide an insulated passage for a transformer conductor through a grounded tank or cover. The 1 kV DIN 42530 and 3 kV DIN 42539 ranges serve low-voltage terminal connections; the 10–52 kV DIN 42531–42534 ranges serve higher-voltage transformer connections, including the indoor and outdoor designs illustrated above.
For transformer terminals requiring 5000–8000 A at 24 or 36 kV, the DIN 42541 high-current range provides the corresponding series.
Clear DIN series selection: The product range is organized by the seven DIN standards, voltage class and rated current, so the applicable series is easy to identify.
Visible construction and dimensions: Product drawings and searchable dimensional tables appear together for checking mounting and connection details.
Product and packaging views: The photos help buyers review the porcelain bushing appearance and packaging before contacting NJREC.
NJREC offers DIN porcelain transformer bushings from 1 to 52 kV and 250 to 8000 A across seven DIN standards. Each series has its own rated voltage and current range in the specifications above.
The DIN 42531–42532 and DIN 42533–42534 model drawings identify indoor and outdoor variants. Check the selected model code and its dimensions when choosing the installation arrangement.
DIN 42541 covers the 24 and 36 kV high-current porcelain transformer bushings rated 5000 or 8000 A.